<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22369</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: "Timeout waiting for plate to enter fully onto conveyor"
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Once it has detected that a plate has arrived at the conveyor entrance sensor,
it allows 150 second for the plate to move fully onto the conveyor and cear the
entrance sensor.  However if the plate reaches the exit sensor before the entrance
sensor is clear, then it procedes to the nexts step (nl. wait for arrival at exit)
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume.  If that fails remove media and select media removed.
</text></DescriptionText>
</OperatorAction>
<Cause>
see above
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/conv.xml</LinkAddress><LinkTitle>Command: conv</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:08 2008 PST
</Updated>
<Links>
</Links>
</Error>